80W Switching mode power supply

PRODUCT > 80W Switching Power Supply > 80W Switching mode power supply

80W Switching mode power supply

■ Features
·INPUT:100-240VAC 50/60Hz
·Output: 5-48V, 0.3-6A
·Global certificates
·No load power consumption<0.21W
·Cooling by free air convection
·MTBF: 30000 hours
·Provide 3 years warranty
·Install fuses on both ends of the Input and Output for double safety
·Protections: Short circuit / Over load / Over voltage / Over temperature
·Meet CEC,DoE Level VI,Energy star.
·Certification: UL,ETL,CUL,GS,CE,BS,SAA,KC,PSE,CB,FCC,EMC,RoHS。
MCNT1205000 MCNT1206000 MCNT1904750 MCNT2403000 MCNT3602000 MCNT4801500
SPECIFICATION
  OUTPUTMODEL NO.  

MCNT1205000

MCNT1206000

 MCNT1904750

MCNT2403000MCNT3602000MCNT4801500
OUTPUT VOLTAGE   12V 12V 19V 24V 36V48V
OUTPUT CURRENT  0-5A  0-6A

0-4.75A 

 0-3A0-2A0-1.5A
OUTPUT POWER 60W72W90W72W72W80W
PFC (MIN.) 0.6 0.6 0.6 0.6 0.60.6
RIPPLE & NOISE (max.) 120mVp-p 120mVp-p 190mVp-p 240mVp-p 360mVp-p480mVp-p
  INPUTINPUT  VOLTAGE 100 ~ 240VAC   
FREQUENCY 50 / 60Hz
INPUT POWERNO LOAD: 0.21W MAX   AT INPUT 100-240VAC  50/60Hz .   LOADING :   100W MAX , AT RATED OUTPUT .
TEMPERATURE RISINGCASE 65 MAX  FOR RATED OUTPUT
EFFICIENCY (MIN)88%
DIELECTRIC WITHSTAND TEST5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND 
 PROTECTIONOVER LOADTHE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT
SHORT CIRCUIT:CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY
ENVIRONMENTWORKING TEMP THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM  -29 TO +45
STORAGETEMPERATURETHE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM  -40 TO +75
RESISTANCE TO HEATWHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3 FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM
RESISTANCE TO MOISTURETHE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT   40 ± 2     AT  90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER.
SAFETY & EMC
SAFETY STANDARDSUL62368   EN60335
EMICISPR22 CLASS
INSULATIONB
  OTHERSMTBFTHEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25
 CONNECTORPLUG5.5*2.1, 5.5*2.5, RCA, XLR, XT60, M16, C14.
CABLE
SPECIFICATION
  OUTPUTMODEL NO.  

MCNT1205000

MCNT1206000

 MCNT1904750

MCNT2403000MCNT3602000MCNT4801500
OUTPUT VOLTAGE   12V 12V 19V 24V 36V48V
OUTPUT CURRENT  0-5A  0-6A

0-4.75A 

 0-3A0-2A0-1.5A
OUTPUT POWER 60W72W90W72W72W80W
PFC (MIN.) 0.6 0.6 0.6 0.6 0.60.6
RIPPLE & NOISE (max.) 120mVp-p 120mVp-p 190mVp-p 240mVp-p 360mVp-p480mVp-p
  INPUTINPUT  VOLTAGE 100 ~ 240VAC   
FREQUENCY 50 / 60Hz
INPUT POWERNO LOAD: 0.21W MAX   AT INPUT 100-240VAC  50/60Hz .   LOADING :   100W MAX , AT RATED OUTPUT .
TEMPERATURE RISINGCASE 65 MAX  FOR RATED OUTPUT
EFFICIENCY (MIN)88%
DIELECTRIC WITHSTAND TEST5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND 
 PROTECTIONOVER LOADTHE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT
SHORT CIRCUIT:CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY
ENVIRONMENTWORKING TEMP THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM  -29 TO +45
STORAGETEMPERATURETHE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM  -40 TO +75
RESISTANCE TO HEATWHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3 FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM
RESISTANCE TO MOISTURETHE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT   40 ± 2     AT  90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER.
SAFETY & EMC
SAFETY STANDARDSUL62368   EN60335
EMICISPR22 CLASS
INSULATIONB
  OTHERSMTBFTHEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25
 CONNECTORPLUG5.5*2.1, 5.5*2.5, RCA, XLR, XT60, M16, C14.
CABLEUL2464 18# 1M length


UL2464 18# 1M length