| SPECIFICATION | ||||||||||||
| OUTPUT | MODEL NO. | MCN5842000 | MCNT5843000 | MCNT5844000 | MCNT5845000 | MCNT5846000 | MCNT5847000 | MCNT58410000 | MCNT58415000 | MCNT58420000 | ||
| OUTPUT VOLTAGE | 58.4V | 58.4V | 58.4V | 58.4V | 58.4V | 58.4V | 58.4V | 58.4V | 58.4V | |||
| OUTPUT CURRENT | 2A | 3A | 4A | 5A | 6A | 7A | 10A | 15A | 20A | |||
| OUTPUT POWER | 116.8W | 175.2W | 233.6W | 292W | 350.4W | 408.8W | 584W | 876W | 1168W | |||
| PFC (MIN.) | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | 0.9 | |||
| RIPPLE & NOISE (max.) | 600mVp-p | 600mVp-p | 600mVp-p | 600mVp-p | 600mVp-p | 600mVp-p | 600mVp-p | 600mVp-p | 600mVp-p | |||
| INPUT | INPUT VOLTAGE | 100 ~ 240VAC | ||||||||||
| FREQUENCY | 50 / 60Hz | |||||||||||
| INPUT POWER | NO LOAD: 0.21W MAX AT INPUT 100-240VAC 50/60Hz . | |||||||||||
| TEMPERATURE RISING | CASE 65 ℃ MAX FOR RATED OUTPUT | |||||||||||
| EFFICIENCY (MIN) | 88% | |||||||||||
| DIELECTRIC WITHSTAND TEST | 5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND | |||||||||||
| PROTECTION | OVER LOAD | THE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT | ||||||||||
| SHORT CIRCUIT: | CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY | |||||||||||
| ENVIRONMENT | WORKING TEMP | THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM -29 ℃ TO +45 ℃ | ||||||||||
| STORAGETEMPERATURE | THE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM -40 ℃ TO +75 ℃ | |||||||||||
| RESISTANCE TO HEAT | WHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3℃ FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM | |||||||||||
| RESISTANCE TO MOISTURE | THE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT 40 ± 2 ℃ AT 90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER. | |||||||||||
| SAFETY & EMC | SAFETY STANDARDS | UL62368 EN60335 | ||||||||||
| EMI | CISPR22 CLASS | |||||||||||
| INSULATION | B | |||||||||||
| OTHERS | MTBF | THEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25 ℃ | ||||||||||
| CONNECTOR | PLUG | 5.5*2.1, 5.5*2.5, RCA, XLR, XT60, M16, C14. | ||||||||||
| CABLE | UL2464 18# 1M length | |||||||||||