60V Lead-acid battery charger

PRODUCT > lead-acid battery charger > 60V Lead-acid battery charger

60V Lead-acid battery charger

■ Features
·INPUT:100-240VAC 50/60Hz
·Output: 73V, 1-15A .
·Global certificates
·No load power consumption<0.21W
·Cooling by free air convection
·MTBF: 30000 hours
·Provide 3 years warranty
·Install fuses on both ends of the Input and Output for double safety
·Protections: Short circuit / Over load / Over voltage / Over temperature
·Meet CEC,DoE Level VI,Energy star.
·Certification: UL,ETL,CUL,GS,CE,BS,SAA,KC,PSE,CB,FCC,EMC,RoHS。
MCNT7302000 MCNT7303000 MCNT7304000 MCNT7305000 MCNT7306000 MCNT7307000 MCNT7308000 MCNT73010000 MCNT73015000
SPECIFICATION
  OUTPUTMODEL NO.  

MCN7302000

MCNT7303000

MCNT7304000

MCNT7305000

MCNT7306000

 MCNT7307000

MCNT7308000MCNT73010000MCNT73015000
OUTPUT VOLTAGE   73V 73V73V 73V 73V73V73V 73V73V
OUTPUT CURRENT 

2A

3A

 4A 5A

6A 

7A 

8A10A15A
OUTPUT POWER146W219W 292W365W438W511W584W730W1095W
PFC (MIN.)  0.9 0.90.9 0.90.9 0.9 0.90.90.9
RIPPLE & NOISE (max.) 800mVp-p 800mVp-p800mVp-p 800mVp-p800mVp-p800mVp-p 800mVp-p800mVp-p800mVp-p
  INPUTINPUT  VOLTAGE 100 ~ 240VAC   
FREQUENCY 50 / 60Hz
INPUT POWERNO LOAD: 0.21W MAX   AT INPUT 100-240VAC  50/60Hz .  
TEMPERATURE RISINGCASE 65 MAX  FOR RATED OUTPUT
EFFICIENCY (MIN)88%
DIELECTRIC WITHSTAND TEST5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND 
 PROTECTIONOVER LOADTHE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT
SHORT CIRCUIT:CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY
ENVIRONMENTWORKING TEMP THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM  -29 TO +45
STORAGETEMPERATURETHE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM  -40 TO +75
RESISTANCE TO HEATWHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3 FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM
RESISTANCE TO MOISTURETHE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT   40 ± 2     AT  90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER.
SAFETY & EMC
SAFETY STANDARDSUL62368   EN60335
EMICISPR22 CLASS
INSULATIONB
  OTHERSMTBFTHEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25
 CONNECTORPLUG5.5*2.1, 5.5*2.5, RCA, XLR, XT60, M16, C14.
CABLEUL2464 18# 1M length


Name
Phone
Email
Corporate name
Address
Leaving Message*
 
Verification code
Submit