24V Lead-acid battery charger

PRODUCT > Battery charger > 24V Lead-acid battery charger

24V Lead-acid battery charger

■ Features
·INPUT:100-240VAC 50/60Hz
·Output: 29.4V, 1-15A .
·Global certificates
·No load power consumption<0.21W
·Cooling by free air convection
·MTBF: 30000 hours
·Provide 3 years warranty
·Install fuses on both ends of the Input and Output for double safety
·Protections: Short circuit / Over load / Over voltage / Over temperature
·Meet CEC,DoE Level VI,Energy star.
·Certification: UL,ETL,CUL,GS,CE,BS,SAA,KC,PSE,CB,FCC,EMC,RoHS。
MCNT2921000 MCNT2922000 MCNT2923000 MCNT2924000 MCNT2925000 MCNT2926000 MCNT2927000 MCNT29280000 MCNT2929000 MCNT29210000 MCNT29215000 MCNT29220000
SPECIFICATION
  OUTPUTMODEL NO.  

MCN2921000

MCNT2922000

MCNT2923000

MCNT2924000

MCNT2925000

 MCNT2926000

MCNT2927000MCNT2928000MCNT29210000
OUTPUT VOLTAGE    29.2V 29.2V29.2V 29.2V 29.2V 29.2V29.2V 29.2V29.2V
OUTPUT CURRENT 

1A

2A

 3A 4A

5A 

6A 

7A8A10A
OUTPUT POWER29.2W58.4W 87.6W116.8W146W175.2W204.4W233.6W292W
PFC (MIN.)  0.6 0.60.9 0.90.9 0.9 0.90.90.9
RIPPLE & NOISE (max.) 300mVp-p 300mVp-p300mVp-p 300mVp-p 300mVp-p300mVp-p 300mVp-p 300mVp-p300mVp-p
  INPUTINPUT  VOLTAGE 100 ~ 240VAC   
FREQUENCY 50 / 60Hz
INPUT POWERNO LOAD: 0.21W MAX   AT INPUT 100-240VAC  50/60Hz .  
TEMPERATURE RISINGCASE 65 MAX  FOR RATED OUTPUT
EFFICIENCY (MIN)88%
DIELECTRIC WITHSTAND TEST5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND 
 PROTECTIONOVER LOADTHE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT
SHORT CIRCUIT:CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY
ENVIRONMENTWORKING TEMP THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM  -29 TO +45
STORAGETEMPERATURETHE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM  -40 TO +75
RESISTANCE TO HEATWHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3 FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM
RESISTANCE TO MOISTURETHE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT   40 ± 2     AT  90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER.
SAFETY & EMC
SAFETY STANDARDSUL62368   EN60335
EMICISPR22 CLASS
INSULATIONB
  OTHERSMTBFTHEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25
 CONNECTORPLUG5.5*2.1, 5.5*2.5, RCA, XLR, XT60, M16, C14.
CABLEUL2464 18# 1M length


Name
Phone
Email
Corporate name
Address
Leaving Message*
 
Verification code
Submit