24W Lithium-ion Battery Charger

PRODUCT > lithium-ion battery charger > 24W Lithium-ion Battery Charger

24W Lithium-ion Battery Charger

■ Features
·INPUT:100-240VAC 50/60Hz
·Output: 8.4-25.2V, 0.3-2A .
·Global certificates
·No load power consumption<0.21W
·Cooling by free air convection
·MTBF: 30000 hours
·Provide 3 years warranty
·Install fuses on both ends of the Input and Output for double safety
·Protections: Short circuit / Over load / Over voltage / Over temperature
·Meet CEC,DoE Level VI,Energy star.
·Certification: UL,ETL,CUL,GS,CE,BS,SAA,KC,PSE,CB,FCC,EMC,RoHS。
MCNT0842000 MCNT1262000 MCNT1681000 MCNT2101000 MCNT2521000 MCNT2940800
SPECIFICATION
  OUTPUTMODEL NO.  

 MCNT0840200

MCNT1260200

MCNT1680100

MCNT2100100MCNT2520100

MCNT2940080

OUTPUT VOLTAGE    8.4V  12.6V 16.8V 21V25.2V 29.4V
OUTPUT CURRENT   2A

  2A 

 1A 

 1A 1A

 0.8A 

OUTPUT POWER  16.8W  25.2W 16.8W 21W25.2W 23.52W
PFC (MIN.)  0.6  0.6 0.6 0.6 0.6 0.6
RIPPLE & NOISE (max.) 100mVp-p  150mVp-p 200mVp-p 250mVp-p 300mVp-p 350mVp-p
  INPUTINPUT  VOLTAGE 100 ~ 240VAC   
FREQUENCY 50 / 60Hz
INPUT POWERNO LOAD: 0.5W MAX   AT INPUT 100-240VAC  50/60Hz .   LOADING :   80W MAX , AT RATED OUTPUT .
TEMPERATURE RISINGCASE 65 MAX  FOR RATED OUTPUT
EFFICIENCY (MIN)88%
DIELECTRIC WITHSTAND TEST5mA 3000VAC FOR 60 SECOND BETWEEN INPUT AND OUTPUT INPUT AND CASE, AT AN ALTERNATIVE POTENIALS 5% HIGHER MAY BE APPLIED FOR 1 SECOND 
 PROTECTIONOVER LOADTHE PRODCT INCLUDES CURRENT FUSE TYPE 250V 3A LOCATED WITHIN INPUT CIRCUIT
SHORT CIRCUIT:CAPABLE OF WITHSTANDING CONTINUOUS SHORT CIRCUIT AND RECOVER AUTOMATICALLY
ENVIRONMENTWORKING TEMP THE OPERATIN TEMPERATURE OF THE PRODUCT SHALL BY FROM  -29 TO +45
STORAGETEMPERATURETHE STORAGE TEMPERATURE OF THE PRODUCT SHALL BY FROM  -40 TO +75
RESISTANCE TO HEATWHEN TESTED WITHIN 10 MINUTES AFTER PRODUCT HAS BEEN PLACED IN A TEST CHAMBER MAINTAINED AT105 ±3 FOR 16 HOURS , THE PRODUCT SHALL COMPLYVAC WITH THE REQUIREMENTS OF 4.7 , DIELECTRIC WITHSTAND TEST , SHALL HAVE INSULATION RESISTANCS NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE INPUT AND THE OUTPUT, INPUT AND CASE TOGETHER , 10 MEGOHMS MINIMUM
RESISTANCE TO MOISTURETHE PRODUCT SHALL BY PLACED IN A TEST CHAMBER MAINTAINED AT   40 ± 2     AT  90% ~ 95% RELATIVE HUMIDITY FOR 6 HOURS . THEN , WHEN TESTING 10 MINUTES SAFTER THE PRODUCT IS TAKEN OUT FROM THE TEST CHAMBER AND WIPED DRY , THE PRODUCT SHALL COMPLY WITH THE REQUIREMENTS OF 4.7 DIELECTRIC WITHSTAND TEST , AND SHALL HAVE INSULATION RESISTANCE NOT LESS THAN STATED BELOW AS MEASURED AT 500VDC 10 MEGOHMS MINIMUM BETWEEN THE PRIMARY AND THE SECONDARY TOGETHER;10 MEGOHMS MINIMUM BETWEEN A SECONDRY THER SECONDRY AND TOGETHER.
SAFETY & EMC
SAFETY STANDARDSUL62368   EN60335
EMICISPR22 CLASS
INSULATIONB
  OTHERSMTBFTHEVDESIGN AND CONSTRUCTION OF THIS PRODUCT EXHIBIT A MINIMUM MEAN TIME BETWEEN FAILURE OF 30000 HOURS FULL RATED LOAD OPERATION AT 25
 CONNECTORPLUG5521, 5525, RCA, XLR, XT60, M16, C14.
CABLEUL2464 18# 1M length
PACKINGSIZE
76*44*31 CM
WEIGHT0.18kg